AST AL30
AST Model AL30 provide the advantage of contactless temperature measurement in non-metallic surfaces and also painted metals, coated or anodised.
AST AL30 is designed for easy integration into standard four-wire system. This format combines the high precision digital signal processing with the simple connection. The AST AL30 pyrometer is used for a target temperature ranging from 0 ° C to 1000 ° C. The electronic assembly is protected by an IP 65 box-resistant stainless steel.
AST AL30 is designed for easy integration into standard four-wire system. This format combines the high precision digital signal processing with the simple connection. The AST AL30 pyrometer is used for a target temperature ranging from 0 ° C to 1000 ° C. The electronic assembly is protected by an IP 65 box-resistant stainless steel.
AST AL30 comes with a USB 2.0 connector cable. The pyrometer can be recharged through the USB port. In this case, no external power supply is required (+ 24V DC required for the analog output operation, laser, RS-232 output / RS-485).
STANDARD SCOPE OF SUPPLY
AST AL30 with Targeting Laser, USB output, USB cable, connection cable 5 m and 1.5 m communication cable.
USE
- Plastic;
- Fluid;
- Eraser;
- Ceramics;
- Wood;
- Glass;
- Coated metals;
- Textiles.
RESOURCES
- High accuracy due to digital linearisation of the output;
- Four-wire form with analog output 4 to 20 mA; 0 to 20 mA; or 0 to 10V;
- Serial communication RS-232 or RS-485;
- 60ms response time (at maximum speed = at maximum speed);
- Very good stability;
- Laser Mira.

ESPECIFICAÇÃO TÉCNICA
Notice:
After the startup of the power supply, keep pyrometer under stable temperature condition for 25-30 minutes for accuracy and resolution. The laser should only be used for targeting purposes. In the normal measurement laser should be turned off for correct measurement.
SOFTWARE "INTRASOFT"
- Emissivity setting;
- Definition of the response time;
- The picker Pico configuration;
- Average temperature adjustment;
- Oline graphics or offline;
- Analog output;
- Data calculations.

COBERTURA DE CAMPO

ACESSÓRIOS
Revestimento de refrigeração de água com flange ajustável
(Referência nº: 8000-02 para PL)

Suporte de montagem ajustável
(Referência nº8000-07)

Unidade de ejeção de ar
(Referência nº 8000-04)

Suporte de montagem ajustável
(Referência nº8000-05)

Exibição e parametrização P-120
(Referência nº 9001-01)

Conversor RS-232<->RS-485
(Referência nº 9000-03)

Unidade de alimentação
(Referência nº 9000-02)

Indicador de temperatura
(Referência nº 9000-01)

DESENHOS DO PIRÔMETRO

Revestimento de refrigeração de água com flange ajustável (Referência nº: 8000-02 para PL)

Unidade de ejeção de ar (Referência nº 8000-04)

Suporte de montagem ajustável (Referência nº8000-07)

Suporte de montagem ajustável (Referência nº8000-05)

STANDARD SCOPE OF SUPPLY
AST AL30 with Targeting Laser, USB output, USB cable, connection cable 5 m and 1.5 m communication cable.
USE
- Plastic;
- Fluid;
- Eraser;
- Ceramics;
- Wood;
- Glass;
- Coated metals;
- Textiles.
RESOURCES
- High accuracy due to digital linearisation of the output;
- Four-wire form with analog output 4 to 20 mA; 0 to 20 mA; or 0 to 10V;
- Serial communication RS-232 or RS-485;
- 60ms response time (at maximum speed = at maximum speed);
- Very good stability;
- Laser Mira.

ESPECIFICAÇÃO TÉCNICA
MODEL | AST AL30 |
measured temperature (Sub adjustable analog range) | 0°C to 1000°C, 75°C to 1000°C (Adjustable analog output) |
Emissivity | 0.1...1 Adjustable |
Spectral field, ? m | 8 ? ...14 ? m |
Photodetector Type | Thermopile |
Response Time | 60msec |
Accuracy | T = 0 to 200 ° C ± 2% of reading ° C or 3 ° C (whichever is greater) T = 201 ° C to 1000 ° C ± 1,5% of reading ° C or 4 ° C (whichever is greater). The instrument must be at a constant room temperature for at least 30 min. |
Repeatability | 0.3% of reading in ° C + 1 ° C (whichever is greater). Instruments must be at a constant room temperature for at least 25-30 min (in connected mode). |
Proportional Distance measurement point | 50:1, 100:1 |
Analog flow | 4-20 mA ou 0-20 mA ou 0-10 V User selectable |
Digital output | UBS 2.0, RS-232/RS-485(Isolated) User selectable |
Energy | 24V DC |
Sight | Pilot Laser (PL) |
Protection Class | IP 65 |
Operating Temperature | 0°C...+70°C, 0°C...+200°C (with refrigerating) |
Isolamento | Fonte de alimentação, saída digital e saída analógica são galvanicamente isolados um contra o outro |
Storage Temperature | -20°C...+70°C |
Dimensions / Weight | Diameter: Ø49.5 mm; Length.: 118mm/ Weight=0.6 kg. |
Adjustable parameters by Software | Emissivity, analog output, address, response time, peak picker, analog output. |
After the startup of the power supply, keep pyrometer under stable temperature condition for 25-30 minutes for accuracy and resolution. The laser should only be used for targeting purposes. In the normal measurement laser should be turned off for correct measurement.
SOFTWARE "INTRASOFT"
- Emissivity setting;
- Definition of the response time;
- The picker Pico configuration;
- Average temperature adjustment;
- Oline graphics or offline;
- Analog output;
- Data calculations.

COBERTURA DE CAMPO

ACESSÓRIOS
Revestimento de refrigeração de água com flange ajustável
(Referência nº: 8000-02 para PL)

Suporte de montagem ajustável
(Referência nº8000-07)

Unidade de ejeção de ar
(Referência nº 8000-04)

Suporte de montagem ajustável
(Referência nº8000-05)

Exibição e parametrização P-120
(Referência nº 9001-01)

Conversor RS-232<->RS-485
(Referência nº 9000-03)

Unidade de alimentação
(Referência nº 9000-02)

Indicador de temperatura
(Referência nº 9000-01)

DESENHOS DO PIRÔMETRO

Revestimento de refrigeração de água com flange ajustável (Referência nº: 8000-02 para PL)

Unidade de ejeção de ar (Referência nº 8000-04)

Suporte de montagem ajustável (Referência nº8000-07)

Suporte de montagem ajustável (Referência nº8000-05)