AST AL514
AST Model AL514 offers the advantage of measuring the temperature of quartz glass surfaces and without contact. AST AL514 is designed for easy integration into standard four-wire system.
This format combines the digital signal of high precision processing with the simple connection. The pyrometer AST AL514 is used for the target temperature ranging from 400 ° C to 2500 ° C. The electronic assembly is protected by durable stainless steel IP65.
This format combines the digital signal of high precision processing with the simple connection. The pyrometer AST AL514 is used for the target temperature ranging from 400 ° C to 2500 ° C. The electronic assembly is protected by durable stainless steel IP65.
The AST AL514 is provided with a USB 2.0 connector cable. The pyrometer can be recharged through the USB port.
In this case, no external power supply is required (+ 24V DC required for the analog output operation, laser, RS-232 output / RS-485).
STANDARD SCOPE OF SUPPLY
AST AL390 with Laser Targeting or aiming lens, USB output, USB cable, connection cable 5 m and 1.5 m communication cable.
USE
- Hardening and bending the glass;
- Measurement of float glass temperature.
RESOURCES
- High accuracy due to digital linearisation;
- Four-wire form with analog output 4 to 20 mA; 0 to 20 mA; or 0 to 10V;
- Serial communication RS-232 or RS-485;
- 60mseg of response time;
- Very good stability.
SAÍDA USB 2.0

TECHNICAL SPECIFICATION
Note: After starting the power supply, keep pyrometer under stable temperature condition for 25-30 minutes for accuracy and resolution. The laser should only be used for targeting purposes. In the normal measurement laser should be turned off for correct measurement.
SOFTWARE "INTRASOFT"
- Emissivity setting;
- Definition of the response time;
- The picker Pico configuration;
- Oline graphics or offline;
- Analog output;
- Data calculations.

COBERTURA DE CAMPO

ACESSÓRIOSRevestimento de refrigeração de água com flange ajustável
(Referência nº: 8000-02 para PL)
(Referência nº 8000-06 para TL)

Suporte de montagem ajustável
(Referência nº8000-07)

Unidade de ejeção de ar
(Referência nº 8000-04)

Suporte de montagem ajustável
(Referência nº8000-05)

Exibição e parametrização P-120
(Referência nº 9001-01)

Conversor RS-232<->RS-485
(Referência nº 9000-03)

Unidade de alimentação
(Referência nº 9000-02)

Indicador de temperatura
(Referência nº 9000-01)

DESENHOS DO PIRÔMETRO

Revestimento de refrigeração de água com flange ajustável (Referência nº: 8000-02 para PL)

Revestimento de refrigeração de água com flange ajustável (Referência nº 8000-06 para TL)

Unidade de ejeção de ar (Referência nº 8000-04)

Suporte de montagem ajustável (Referência nº8000-07)

Suporte de montagem ajustável (Referência nº8000-05)

In this case, no external power supply is required (+ 24V DC required for the analog output operation, laser, RS-232 output / RS-485).
STANDARD SCOPE OF SUPPLY
AST AL390 with Laser Targeting or aiming lens, USB output, USB cable, connection cable 5 m and 1.5 m communication cable.
USE
- Hardening and bending the glass;
- Measurement of float glass temperature.
RESOURCES
- High accuracy due to digital linearisation;
- Four-wire form with analog output 4 to 20 mA; 0 to 20 mA; or 0 to 10V;
- Serial communication RS-232 or RS-485;
- 60mseg of response time;
- Very good stability.
SAÍDA USB 2.0

TECHNICAL SPECIFICATION
MODEL | AST AL30 |
measured temperature (Under adjustable analog range) | 400° C to 2500 ° C |
Emissivity | 0.2 ... 1 Adjustable |
Spectral field, ? m | 5,14 ? m |
Photodetector Type | Thermopile |
Response Time | 60msec. |
Accuracy (Room temperature at 23 ± 5 ° C) ? = 1, 1 sec response time | <500 ° C is 1.5% accuracy of the temperature reading; > 500 ° C is 1% precision temperature reading; (The instrument must be in constant temperature environment for at least 25-30 min) |
Repeatability | 0.3% of reading in ° C + 1 ° C (whichever is greater). Instruments must be at a constant room temperature for at least 25-30 min (in connected mode). |
Proportional Distance measurement point | 50:1 |
Analog flow | 4-20mA or 0-20mA or 0-10V selectable by the user |
Digital Output | USB 2.0, RS-232 / RS-485 (Remote) User selectable |
Energy | 24V DC |
Sight | Laser Pilot (PL) or or through the viewfinder lens (TL) |
Laser Power | <1m W |
Protection Class | IP 65 |
Operating Temperature | 0°C...+70°C, 0°C...+200°C (with refrigeration) |
Isolation | Power supply, digital output and analog output are galvanically isolated against each other |
Storage Temperature | -20°C...+70°C |
Dimensions / Weight | Diameter: Ø49.5 mm; Comp.: 118mm/ Weight=0.6 kg. |
Adjustable parameters via Software | Emissivity, analog output, address, response time, peak picker, analog output. |
SOFTWARE "INTRASOFT"
- Emissivity setting;
- Definition of the response time;
- The picker Pico configuration;
- Oline graphics or offline;
- Analog output;
- Data calculations.

COBERTURA DE CAMPO

ACESSÓRIOSRevestimento de refrigeração de água com flange ajustável
(Referência nº: 8000-02 para PL)
(Referência nº 8000-06 para TL)

Suporte de montagem ajustável
(Referência nº8000-07)

Unidade de ejeção de ar
(Referência nº 8000-04)

Suporte de montagem ajustável
(Referência nº8000-05)

Exibição e parametrização P-120
(Referência nº 9001-01)

Conversor RS-232<->RS-485
(Referência nº 9000-03)

Unidade de alimentação
(Referência nº 9000-02)

Indicador de temperatura
(Referência nº 9000-01)

DESENHOS DO PIRÔMETRO

Revestimento de refrigeração de água com flange ajustável (Referência nº: 8000-02 para PL)

Revestimento de refrigeração de água com flange ajustável (Referência nº 8000-06 para TL)

Unidade de ejeção de ar (Referência nº 8000-04)

Suporte de montagem ajustável (Referência nº8000-07)

Suporte de montagem ajustável (Referência nº8000-05)