AST TL8
AST TL8 series of digital pyrometer provides high performance and low maintenance measurement of temperatures without contact, required in industrial environments.
AST series TL8 are provided with TTL output. The emissivity analog output sub-range, response time can be pre-set or factory set by software service.
This allows the instrument to be adapted to various measuring tasks.
AST series TL8 are provided with TTL output. The emissivity analog output sub-range, response time can be pre-set or factory set by software service.
This allows the instrument to be adapted to various measuring tasks.
This pyrometer has solid body in stainless steel housing, which provides high operating safety, even in rough industrial environment.
STANDARD SPACE SUPPLY
AST TL8 with connecting cable 3 meters, TTL output, relay output, analog output 0-5V, 4 ... 20mA, thermocouple type K or J output (Select any analog output while ordering).
OPTIONAL ACCESSORIES
TL8 series is provided with TTL output. Using the USB key and the pyrometer software can be connected to PC for configuration setting, data logging and output selection.

USE
- Plastic;
- Wood;
- Paper;
- Glass;
- Fluid;
- Painted and rusty surface;
- Eraser;
- Textiles;
- Ceramics.
CHARACTERISTICS
- Robust and compact;
- Temperature range 0 ° C to 500 ° C;
- Spot Size 15: 1;
- Response time 100msec. to 10 sec .;
- TTL output and software service;
- Alarm output;
- Analog output 0-5V, 4 ... 20mA, T / C output type K or J (Select any analog output while ordering);

TECHNICAL SPECIFICATION
FIELD COVERAGE

ACESSÓRIOS
Unidade de ar expurgo para Cabeça Ótica II (Referência Nº 8200-01)

Montagem ajustável para Cabeça Ótica II (Referência Nº 8200-03)

Unidade de abastecimento de energia (Referência Nº9000-02)

Interface USB para saída TTL (Referência Nº9000-07)

STANDARD SPACE SUPPLY
AST TL8 with connecting cable 3 meters, TTL output, relay output, analog output 0-5V, 4 ... 20mA, thermocouple type K or J output (Select any analog output while ordering).
OPTIONAL ACCESSORIES
TL8 series is provided with TTL output. Using the USB key and the pyrometer software can be connected to PC for configuration setting, data logging and output selection.

USE
- Plastic;
- Wood;
- Paper;
- Glass;
- Fluid;
- Painted and rusty surface;
- Eraser;
- Textiles;
- Ceramics.
CHARACTERISTICS
- Robust and compact;
- Temperature range 0 ° C to 500 ° C;
- Spot Size 15: 1;
- Response time 100msec. to 10 sec .;
- TTL output and software service;
- Alarm output;
- Analog output 0-5V, 4 ... 20mA, T / C output type K or J (Select any analog output while ordering);

TECHNICAL SPECIFICATION
MODELO | AST TL8 |
Temperatura medida (Sub faixa analógica ajustável) | 0°C – 500°C |
Campo espectral, ?m | 8-14 ?m |
Tipo de Detector | Termopilha |
Vazão Analógica | 0-5 V, 4-20mA, termopar com saída tipo K ou J (Selecione qualquer saída analógica enquanto ordenação). |
Saída Digital | Saída TTL |
Saída de Alarme | 24V DC, carga <100mA (Transistor) |
Emissividade ? | 0.1...1.2 ajustável |
Tempo de Resposta | 100 mseg. Ajustável até 10 seg |
Distância à relação de tamanho de ponto | 15:1 |
Incerteza de medida | +- 2% do valor medido ou +- 3°C do que for maior (a ? =1, Tamb=25°C, &epsilon=1sec) |
Repetibilidade | +- 5% do valor medido ou +-1°C do que for maior (a ? =1, Tamb=25°C, ?=1sec) |
Resolução | 0.2°C |
Energia | 12V a 25V DC (I ?80mA) |
Temperatura ambiente | 0 a 70°C |
Temperatura armazenamento | -20°C a 70°C |
Carcaça | Aço inoxidável |
Classe de proteção | IP 65 |
Peso | Dia=25mm; Larg=103mm; Peso=0.200Kg |
FIELD COVERAGE

ACESSÓRIOS
Unidade de ar expurgo para Cabeça Ótica II (Referência Nº 8200-01)

Montagem ajustável para Cabeça Ótica II (Referência Nº 8200-03)

Unidade de abastecimento de energia (Referência Nº9000-02)

Interface USB para saída TTL (Referência Nº9000-07)