Vibronic Level Switch
It secure point level measurements as well as high and low level alarms to prevent overfill; The vibrating fork technology identify the difference in liquid by resonance principal, resonance period is in proportion to the density of liquid; When the forks come in contact with a liquid, the resonant period will show difference between the liquid and air, then the differences between the liquid and air will be detected and the device will switch the alarms.

Aplicação
- Detecção de Nível Alto e Baixo para tanque diferente;
- Detecção de nível alto e baixo para líquido em tubo;
Item | Parameter | Item | Parameter |
Measurement Range | Density >_ 500kg/m³ | Voltage | DC10V~40V |
Ambient Temp. | -40ºC ~ + 70ºC ou personalizado | Current | <_ 20mA |
Output | Saída de corrente e ligar / desligar Saída da chave com a chave PNP triplo | Working Temp. | -40?~+60? |
Sensor type | Termopar PT100+T ou todos os PT100 | IP Protection | IP65 |
Length | ? 30m | Cable Inlet | 2ºG1/2 |
Flange | DN80 PN10, DN50 PN10 | Ex Rating | Ex d II C T6 Gb |
Material | Aço inoxidável |