The Alutal has a ACCREDITED Calibration Laboratory for CGCRE, the temperature area, CAL-0522 certificate in accordance with standard ISO / IEC 17025, with high-tech equipment and metrologists trained to offer calibration services with reliability, ensuring all sensors, instruments and extension cables / compensation comply with the applicable rules.

request quote

The product

The calibration provided by Alutal intended to ensure the reliability of the measurements and consequently, the quality of the finished product, providing a number of advantages:

• Ensure the traceability of measurements, ie, with respect to comparative references to national or international standards;
• Reduce variations in technical specifications of products;
• Preventing defects as part of preventive maintenance, and match the measurements;
• Standardize work;

Services offered in the lab facility
1) Temperature (accredited service)
2) Temperature (tracked service)
3) Pressure (tracked service)

NOTE: The measurement and calibration capabilities (CMC) is the smallest uncertainty that the laboratory is able to get, with a coverage probability or level of confidence of approximately 95%.

Services Offered Customer Premises
In many companies, measuring instruments are essential, so, remove them and send them to the laboratory, can result in interruption of the process for a long period and, therefore, the Alutal offers field calibration service and has the necessary structure to perform the calibration of measuring instruments in the same laboratory conditions.

• Temperature
Accredited Calibration / Screened: the same calibration items in the lab facility.

• Pressure
Screened calibration: the same calibration items in the lab facility.

• Flow Measurement
The flow measurement of a fluid, whether liquid or gas, is generally a critical parameter in many industrial processes. Most of the operations that can be connected to the “recipe” basic process – knowing that the fluid is right in the right place at the right time. Therefore, it is necessary to perform measurements accurate and reliable flow rates, because they can influence product quality, health and safety, and ultimately can make the difference between a profit or a loss occur.

Therefore, in accordance with the API standard MPMS 5.8, the Alutal accomplishes these flow measurements, compared by means of ultrasound sensors (transit time method) using clamp-on system, which need not be removed from the instrument line .

• Flow Test Hydrants
The perfect functioning of the fire fighting system hydrants is of fundamental importance, since it depends on the physical integrity of people and also of assets therefore have to undergo periodic maintenance. We carry out flow tests on fire hydrants using Pitot tube, in accordance with IT-22 Fire Department and NFPA-291 standard.

request quote
folders
tables

1) Temperatura (serviço acreditado)

Tabela Especificação em Português / Specifications Table in English

Descrição do Serviço Faixa CMC
Indicador / Controlador Analógico / Digital para Outros Sensores -100 até 400ºC 0,12°C
Indicador / Controlador Analógico / Digital para Sensor Termopar -100 até 1700ºC 0,5°C
Transmissor de Temperatura para Outros Sensores -100 até 400ºC 0,12ºC
Transmissor de Temperatura para Sensor Termopar -100 até 1700ºC 0,5ºC
Cabo de Compensação / Extensão -20 até < 0ºC 1,0ºC
Termômetro Analógico / Digital com Outros Sensores -20 até < 0ºC 0,3 ºC
0ºC 0,2ºC
> 0 até 300ºC 0,3ºC
>300 até 350°C 0,4ºC
Termômetro Analógico / Digital com Sensor Termopar -20 até < 300ºC 1,0ºC
> 300 até 400ºC 1,7ºC
> 400 até 500ºC 2,0ºC
> 500 até 600ºC 2,2ºC
> 600 até 700ºC 2,5ºC
> 700 até 800ºC 2,7ºC
> 800 até 900ºC 3,0ºC
> 900 até 1000ºC 3,3ºC
> 1000 até 1100ºC 3,5ºC
Termômetro de Resistência -20 até < 0 ºC 0,3ºC
0ºC 0,2ºC
> 0 até 300ºC 0,3ºC
>300 até 350°C 0,4ºC
Termopar de Metais Básicos -20 até 300ºC 1,0ºC
> 300 até 400ºC 1,7 ºC
>400 até 500ºC 2,0ºC
> 500 até 600ºC 2,2ºC
> 600 até 700ºC 2,5º C
> 700 até 800ºC 2,7ºC
> 800 até 900ºC 3,0ºC
> 900 até 1000ºC 3,3ºC
> 1000 até 1100ºC 3,5ºC
Termopar de Metais Nobres 50 até 300 ºC 1,2ºC
>300 até 400ºC 1,7ºC
>400 até 500ºC 2,0ºC
> 500 até 600ºC 2,3ºC
> 600 até 700ºC 2,5ºC
> 700 até 800ºC 2,8ºC
> 800 até 900ºC 3,0ºC
> 900 até 1000ºC 3,3ºC
> 1000 até 1100ºC 3,6ºC
Transmissor de Temperatura com Outros Sensores -20 até < 0ºC 0,3ºC
0 ºC 0,2ºC
> 0 até 300ºC 0,3ºC
>300 até 350°C 0,4ºC
Transmissor de Temperatura com Sensor Termopar -20 até 300ºC 1,0ºC
> 300 até 400ºC 1,7ºC
>400 até 500ºC 2,0ºC
> 500 até 600ºC 2,2ºC
> 600 até 700ºC 2,5ºC
> 700 até 800ºC 2,7ºC
> 800 até 900ºC 3,0ºC
> 900 até 1000ºC 3,3ºC
> 1000 até 1100ºC 3,5ºC
Service Description Band CMC
Indicator / Controller Analog / Digital to Other Sensors -100 até 400ºC 0,12°C
Indicator / Analog / Digital Controller for Thermocouple Sensor -100 até 1700ºC 0,5°C
Temperature Transmitter for Other Sensors -100 até 400ºC 0,12ºC
Temperature Transmitter for Thermocouple Sensor -100 até 1700ºC 0,5ºC
Cable Compensation / Extension -20 até < 0ºC 1,0ºC
Analog / Digital Thermometer with Other Sensors -20 até < 0ºC
0ºC
0,2ºC > 0 até 300ºC
>300 até 350°C

0,3ºC
0,2°C
0,4°C
0,3°C
Thermometer Analog / Digital Sensor with Thermocouple -20 até < 300ºC
> 300 até 400ºC
> 400 até 500ºC
> 500 até 600ºC
> 600 até 700ºC
> 700 até 800ºC
> 800 até 900ºC
> 900 até 1000ºC
> 1000 até 1100ºC
1,0ºC
1,7ºC
2,0ºC
2,2ºC
2,5ºC
2,7ºC
3,0ºC
3,3ºC
3,5ºC
Resistance Thermometer -20 até < 0 ºC
0ºC
0,2ºC
> 0 até 300ºC
>300 até 350°C

0,3°C
0,2°C
0,3°C
0,4°C
Thermocouple Base Metals -20 até 300ºC
> 300 até 400ºC
>400 até 500ºC
> 500 até 600ºC
> 600 até 700ºC
> 700 até 800ºC
> 800 até 900ºC
> 900 até 1000ºC
> 1000 até 1100ºC
1,0ºC
1,7 ºC
2,0ºC
2,2ºC
2,5º C
2,7ºC
3,0ºC
3,3ºC
3,5ºC
Thermocouple Noble Metals > 50 até 300 ºC
> 300 até 400ºC
> 400 até 500ºC
> 500 até 600ºC
> 600 até 700ºC
> 700 até 800ºC
> 800 até 900ºC
> 900 até 1000ºC
> 1000 até 1100ºC
1,2ºC
1,7ºC
2,0ºC
2,3ºC
2,5ºC
2,8ºC
3,0ºC
3,3ºC
3,6ºC
Temperature Transmitter with Other Sensors -20 até < 0ºC
0 ºC
> 0 até 300ºC
0,3ºC
0,2ºC
0,3ºC

Temperature Transmitter with Thermocouple Sensor >-20 até 300ºC
> 300 até 400ºC
>400 até 500ºC
> 500 até 600ºC
> 600 até 700ºC
> 700 até 800ºC
> 800 até 900ºC
> 900 até 1000ºC
> 1000 até 1100ºC
1,0ºC
1,7ºC
2,0ºC
2,2ºC
2,5ºC
2,7ºC
3,0ºC
3,3ºC
3,5ºC

1) Temperatura (serviço acreditado)

2) Temperatura (serviço rastreado)

Tabela Especificação em Português / Specifications Table in English

Descrição do Serviço Faixa CMC
Termostato Analógico -20 até 150ºC 1,2ºC
> 150 até 600ºC 1,8ºC
> 600 até 1100ºC 2,7ºC
Termostato Digital -20 até 150ºC 0,8ºC
> 150 até 600ºC 1,5ºC
> 600 até 1100ºC 2,3ºC
Termômetro Bimetálico -20 até 150ºC 1,2ºC
> 150 até 600ºC 1,8ºC

Service description Band CMC
Analog thermostat >-20 up to 150ºC
> 150 up to 600ºC
> 600 up to 1100ºC
1,2ºC
1,8ºC
2,7ºC

Digital thermostat >-20 up to 150ºC
> 150 up to 600ºC
> 600 up to 1100ºC
0,8ºC
1,5ºC
2,3ºC
Bimetallic thermometer -20 up to 150ºC
> 150 up to 600ºC

1,2ºC
1,8ºC

2) Temperatura (serviço rastreado)

3) Pressão (serviço rastreado)

Tabela Especificação em Português / Specifications Table in English

Descrição do Serviço Faixa CMC
Manômetro Digital / Analógico 0 até 2 bar 0,13 bar
> 2 até 35 bar 0,26 bar
> 35 até 690 bar 0,68 bar
Pressostato Digital / Analógico -1 até 2 bar 0,13 bar
> 2 até 35 bar 0,19 bar
> 35 até 690 bar 0,72 bar
Transmissor Digital / Analógico -1 até 2 bar 0,15 bar
> 2 até 35 bar 0,25 bar
> 35 até 690 bar 0,75 bar
Vacuômetro Digital / Analógico -1 até 0 bar 0,11 bar

Service description Band CMC
Pressure Gauge Digital / Analog 0 to 2 bar
> 2 to 35 bar
> 35 to 690 bar
0,13 bar
0,26 bar
0,68 bar
Pressure Switch Digital / Analog -1 To 2 bar
> 2 to 35 bar
> 35 to 690 bar
0,13 bar
0,19 bar
0,72 bar
Digital Transmitter / Analog -1 To 2 bar
> 2 to 35 bar
> 35 to 690 bar
0,15 bar
0,25 bar
0,75 bar
Vacuum gauge Digital / Analog -1 to 0 bar 0,11 bar

3) Pressão (serviço rastreado)

100%