The product
• Sensor: Uses high-quality catalytic sensor specially designed to detect LPG, Methane, Petrol Vapour, Butane, Propane, and Hydrogen gases in 0-100%LEL.
• Certification: ATEX and IECEx certified PE Series ready to use in explosive atmosphere safely
• Connection: Provides universal standard 4-20mA analog output
• Entry: 1 x 1/2? NPT cable entries
• Body: Aluminium die-cast body and sensor head superb performance under harsh environmental conditions with IP65 protection class.
• Remote Control: Detector status can be monitored Prosense Gas Monitoring software remotely.
• Relay Contacts: PE-2R+ relay module integrated PE Series detectors can manage other equipments or link to firefighting panels.
Specification
| Sensor Technology | Catalytic | 
| Output Signal | 4-20mA Analog | 
| Accuracy | %1 | 
| Sensor Warm-Up | 60sec | 
| Operating Temperature | -40°C ~ +70°C | 
| Response Time(T90) | <15sec | 
| Humidity | 5 ~ 95%RH Non-Condensing | 
| Input | Min 10VDC – Max 28VDC – Nominal 24VDC | 
| Power Consumption | Max. 4W | 
| Relay Outputs | 2 Relay Contacts (Alarm1-Fault or Alarm1-Alarm2) | 
| IP Rating | IP65 | 
| Junction Box | Epoxy Painted Die-Cast Aluminum | 
| Sensor Head | Nickel-Plated Brass | 
| Dimensions/Weight | 172,5×118,15x88mm / 1150gr | 
| ATEX Marking | II 2G Ex db IIC T4-T5 Gb | 
| Hazardous Class | Zone 1 or Zone 2 | 
| Certificates | IMQ 19 ATEX 045 X IECEx IMQ 18.0009X | 
| Standards | IEC EN 60079-0 IEC EN 60079-1 IEC EN 60079-18 | 
Gases
• LPG – (LPG)
• Methane-CH4 – (Methane-CH4)
• Petrol Vapour-Gasoline – (Petrol Vapour-Gasoline)
• Butane-C4H10 – (Butane-C4H10)
• Propane-C3H8 – (Propane-C3H8)
• Hydrogen-H2 – (Hydrogen-H2)
 
                                   
                                      
                                   
                                      
                                   
                    
                   
                    
                   
                    
                   
              